Anti Corrosion L Bolt Concrete Anchor Stainless Steel Foundation Bolts M18 GB 5782-86

Contact Now
Handan city Yongnian District Maide Fasteners Co. Ltd
City:handan
Province/State:hebei
Country/Region:china
Contact Now

Anti Corrosion L Bolt Concrete Anchor Stainless Steel Foundation Bolts M18 GB 5782-86

Ask Latest Price
Video Channel
Brand Name :MD
Model Number :m24-m36
Certification :ISO
Place of Origin :Hebei,China
MOQ :1TON
Payment Terms :L/C, T/T
Delivery Time :5-8 Work Days
Packaging Details :solid bicycle saddle, 50pcs/carton
Surface Treatment :YZP/HDG/ Powder Coating
Material :Q235/ Q345/ C20/ C45
Standard :DIN/GB/ EN / Etc
Color :White/ Black/ Yellow
Payment Term :L/C, T/T, Visa Card
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Corrosion Resistant Foundation Anchor Bolts M18 GB 5782-86 10.9 Grade

Product Description

Size: M10-M48 ;

Surface treatment: black coating, electroplate, painting, phosphatizing

Galvanizing technique: hot dipped galvanized , powder coating, zinc electric,

Thread : full , half, coarse thread, fin pitch thread,

Pitch: MF/UNC/UNF/UNEF

Grade: 4.8;6.8;8.8; 10.9; 12.9;

Standard : DIN/GB/EN/ASME

Material : steel C45, Q235, C20 ;

Alloy steel: SCM435, 20Mn TiB , 35CrMo, 42CrMo ;

Usage : foundation connection, cable connecting, construction buildings, high-way fencing, vehicle accessories;

Foundation Anchor Bolts is designed to be embedded in a concrete foundation and used as a base for fixing various machines and equipment. The 7 word Foundation Anchor Bolts is the more commonly used one in Foundation Anchor Bolts. Generally made of Q235 steel, high-strength use of Q345B or 16Mn material processing, also useful 40Cr material processing 8.8 strength products, occasionally useful secondary or tertiary rebar processing. Foundation Anchor Bolts has different types of wool, thick rods, and thin rods. Raw materials, ie wool, are not restructured, and they are directly processed by round steel or wire rods; the thick rods, or A-type, and the fine rods, or B-type, are all converted from steel rods to the correspondingly required rod diameters. Welded Foundation Anchor Bolts are made by single head bolts after welding stiffened iron plates. Its anti-pulling ability is strong. According to the different conditions used, they can reach grades 3.6, 4.8, 6.8, and 8.8. The 3.6-level 7 character Foundation Anchor Bolts has the tensile strength of the steel itself. The Foundation Anchor Bolts directly processed with Q345B or 16Mn raw materials can achieve a tensile strength of 5.8. The tensile strength of grades 4.8, 5.8, 6.8 and 8.8 refers to the provisions for mechanical properties in GB/T 3098.1.

Specification

Size Weight(kg)
M20*300 0.854
M20*400 1.06
M20*500 1.27
M20*630 1.54
M24*300 1.23
M24*400 1.53
M24*500 1.83
M24*630 3.33
M24*800 2.73
M30*400 2.68
M30*500 3.15
M36*800 7
M36*1000 8.37
M42*630 7.97
M42*800 9.57
M42*1000 11.46
M42*1250 13.87
M48*630 10.93
M48*800 13.03
M48*1250 18.58
M48*1500 21.67

Classification

Foundation Anchor Bolts can be divided into Fixed Foundation Anchor Bolts, Activity Foundation Anchor Bolts, Expansion Anchor Foundation Bolts and Bonding Foundation Anchor Bolts. According to the different shapes, they are divided into: L-shaped embedded bolts, 9-shaped embedded bolts, U-shaped embedded bolts, welded pre-embedded bolts, and embedded bolts on the bottom plate.

Use

1. The fixed Foundation Anchor Bolts, also known as the short-foundation Anchor Bolts, are watered together with the foundation to secure equipment without strong vibration and shock.


2, Activity Foundation Anchor Bolts, also known as the long Foundation Anchor Bolts, is a detachable Foundation Anchor Bolts, used to fix heavy machinery and equipment working with strong vibration and impact.


3, expansion anchor Foundation Anchor Bolts are often used for fixed stationary equipment or auxiliary equipment. The Anchor Anchor Bolts shall be installed in such a way that the distance from the centre of the bolt to the base edge is not less than 7 times the anchorage of the Anchor Bolt, and the anchorage of the Anchor Bolt shall not be less than 10 MPa; there shall be no cracks in the borehole. Care should be taken to prevent the drill bit from colliding with the reinforcing steel or buried pipe in the foundation; the diameter and depth of the drill hole should match the anchor anchor Foundation Anchor Bolts.


4, bonding Foundation Anchor Bolts is a Foundation Anchor Bolts commonly used in recent years, its method and requirements with expansion anchor Foundation Anchor Bolts. However, when the adhesive is attached, the debris in the hole should be blown off and must not be affected by moisture.